Condition: | New |
---|---|
Customized: | Customized |
Certification: | ISO9001 |
Still deciding? Get samples of US$ 50/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Vertical motor principle demonstrator
Product Introduction
The instrument is designed according to the principle that the energized coil rotates in the magnetic field and the closed coil rotates in the magnetic field to generate current. The instrument is composed of "U" shaped bracket, armature, magnet, collector ring, brush, base, upper cover of mobile phone, etc.
The electric brush (6) is a rectangular multi turn coil, which is wrapped on the insulating plastic frame. The two ends of the coil are respectively connected to the two copper rings of the collector ring (1), and red and blue indicator lights (9) are connected on both sides of the armature and fixed on the plastic frame. Armature and commutator are installed on the same shaft (8), and the lower end of the shaft supports the "U" type bracket (5).
The "U" shaped bracket is made of ABS injection molding. A permanent magnet (11) is installed at the hollow parts on both sides of the nail, representing the two poles of the "U" shaped magnet.
The upper cover plate is equipped with a pair of terminals (4) and connected with the corresponding brush holder (3), which can be used for installing circuit boards and external power supplies. One end of the brush (2) is installed on the brush holder, and the other end is in contact with the collector ring copper ring, which can move up and down the brush holder to adjust the contact position.
Product Specification
Product name | Vertical motor principle demonstrator |
Requirements for power supply | When demonstrating the principle of DC motor, connect the DC power supply (dry battery or student power supply) with a voltage of 4V to 6V. The armature can rotate flexibly and accelerate with the increase of voltage. When demonstrating the principles of AC and DC generators, shake the rocker, the output current can make the pointer of J0401 demonstration ammeter (ammeter gear) deflect to the left, right or one side, and the full scale (100Ua) |
Work environment | The temperature is - 10 ºC~+40 ºC, and the relative humidity is not more than 85% |
Starting voltage | 3.5V |
Operating current | 0.63A |
Material | Mental |
Size | 200×70×290mm |
Product feature and application
This instrument can be used to demonstrate the structure and working principle of DC motor and AC/DC generator in junior high school physics teaching. It is a multi-functional combined demonstration motor. The instrument is novel in design and simple in structure. It adopts a vertical armature structure, with large visibility, intuitive and easy to understand, and good demonstration effect. The instrument uses a permanent magnet as the magnetic pole.
Maintenance and precautions
1. Special attention shall be paid to the fact that the armature will not rotate when conducting motor test through strong current, such as after being energized. Cut off the power supply immediately and check the cause. Do not power on the armature for a long time when it is not rotating to avoid burning the armature.
2. The brush and the copper ring of the collector ring shall be kept clean and in good contact. The contact pressure between the brush and the copper ring shall be appropriate to improve the sensitivity of the armature rotation.
3. When conducting motor test, do not connect the circuit board between two terminals to avoid burning the LED on the circuit board.
4. When conducting DC motor test, if the power on voltage exceeds 6V, do not close the indicator switch to avoid burning the indicator. If the electric ball is burnt, remove the indicator lamp cover from the plastic frame to replace it.
5. When installing two permanent magnets, it should be noted that the color of this sticker (i.e., the magnetic pole) is consistent with the color of the "U" bracket, and the red and blue sides of this sticker should be placed against the red and blue sides respectively. Otherwise, if the two magnetic poles are confused, the experiment cannot be carried out.
6. The instrument shall be stored in a dry place and shall be protected from moisture and dust.